PV1100 Plus Series (1.2KVA-2.4KVA)
FEATURES
- Simulated sine wave inverter
- Built-in 50A PWM Solar Charge Controller
- MFD (multi-function display)
- 10A or 20A standard charging current from utility
- Long Range diesel tank allows for longer run times (270L)
- AC/solar priority for output via MFD
- AC/solar priority for charging via MFD
- 3 steps charging algorithm
- Overload & short-circuit protection
- Deep discharge protection
- Auto restart while AC/solar is recovering
MODEL | PV11-1200 Plus | PV11-1800 Plus | PV11-2400 Plus | ||
---|---|---|---|---|---|
Nominal Battery System Voltage | 12VDC | 12VDC | 24VDC | ||
NVERTER OUTPUT | |||||
Rated Power | 1200VA/720W | 1800VA/1000W | 2400VA/1440W | ||
Waveform | Modifided Sine-wave | ||||
Nominal Output Voltage RMS | 230V | ||||
Output Voltage Regulation | +10/-18% | ||||
Output Frequency | 50Hz/60Hz +/-1 Hz | ||||
Inverter Efficiency(Peak) | >80% | ||||
Line Mode Efficiency | >98% | ||||
Typical Transfer Time | Typical 15~20ms 40ms max | ||||
AC INPUT | |||||
Voltage | 230VAC | ||||
Selectable Voltage Range-Narrow | 170~280VAC | ||||
Selectable Voltage Range-Wide | 90~280VAC | ||||
Frequency Range | 40Hz-70Hz (Auto sensing) | ||||
BATTERY | |||||
Nominal Input Voltage | 12VDC | 24VDC | |||
Minimum Start Voltage | 10.5VDC | 21.0VDC | |||
Low Battery Alarm | 10.4VDC (min) | 20.8VDC (min) | |||
Low Battery Cutoff | 9.9~12VDC (Can be set) | 19.8~124VDC (Can be set) | |||
High Voltage Cutoff | 15.0VDC (max) | 30.0VDC (max) | |||
SOLAR CHARGER & AC CHARGER | |||||
Maximum PV Charge Current | 50A (max) | ||||
Maximum PV Array Power | 450W/750W | 900W/1500W | |||
PWM Range @ Operating Voltage | 16~55VDC | ||||
Maximum PV Array Open Circuit Voltage | 55VDC | ||||
Maximum Efficiency | >95% | ||||
Standby Power Consumption | <2W | ||||
AC Charger Voltage | 14.4(max) | 28.8(max) | |||
AC Charging Current | 10A / 20A (Can be set) | ||||
Maximum Charge Current | 10-50A (Can be set) | ||||
BYPASS & PROTECTION | |||||
Nominal Input Frequency | 40Hz - 70Hz | ||||
Overload Protection (SMPS Load) | FUSE | ||||
Output Short Circuit Protection | FUSE | ||||
Bypass Fuse Rating | 10A | ||||
Max Bypass Current | 10Amp | ||||
MECHANICAL SPECIFICATIONS | |||||
Machine Dimensions (W*H*D) | 231*290*92mm | ||||
Package Dimensions (W*H*D) | 595*375*315mm | ||||
Net Weight (kg) | 2.8 | 4.0 | |||
Gross Weight (kg) | 3.5 | 4.7 | |||
OTHER | |||||
Operation Temperature Range | 0°C to 50°C | ||||
Audible Noise | 50dB MAX | ||||
Display | LED+LCD | ||||
Loading(20GP/40GP/40HQ) | 1700pcs / 3400pcs / 4100pcs |