PV3300 TLV Split Phase Series (1-6KW)

CATEGORIES: Solar Inverter

This is a multi-function inverter/charger, combining functions of inverter, MPPT50A/80A solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.

FEATURES

  • Pure sine wave output
  • Friendly user interface;MFD (multi-function display)
  • 3 Steps charging
  • Overload and short-circuit protection
  • Set charging voltage/charging current
  • Battery low voltage shutdown point can be set to 10/10.5/11V
  • Set utility priority/ Battery priority
  • Set utility input wide/narrow range
  • Inverter voltage can be set to 100/110/120;frequency can be set to 50/60Hz
  • Set utility charging on/off switch
  • Built-in 80A MPPT charger


MODEL PV33- 1012 TLV PV33- 1024 TLV PV33- 1512 TLV PV33- 1524 TLV PV33- 2012 TLV PV33- 2024 TLV PV33- 3024 TLV PV33- 3048 TLV PV33- 4024 TLV PV33- 4048 TLV PV33- 5048 TLV PV33- 6048 TLV
Inverter Output
Rated power 1KW 1.5KW 2KW 3KW 4KW 5KW 6KW
Power factor 1
Wave form Pure sine wave
Output voltage RMS 100V 110V 120VAC(200V 220V 240VAC)±10%
Output frequency 50Hz or 60Hz (±0.3Hz)
Inverter efficiency (peak) >85%
Overload 100%<Load<110% (alarm 5min then stop output ) 110%<Load<125% (alarm 60s then stop output) Load > 125% (alarm 10s then stop output )
Surge rating 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 15000VA
Capable of starting electric motor 1P 1P 1.5P 1.5P 2P 3P
Battery
Battery voltage 12VDC/24VDC 24VDC/48VDC 48VDC
Minimum start voltage 11VDC/22VDC/44VDC
Low battery voltage cut off (Low voltage fault code04)1010.511V for 12V mode; 202122V for 24V model ; 404244V for 48v model
Low battery voltage alarm Add 0.5V battery:(Low battery alarm one second one time) (10 10.5 11V)+0.5VDC for 12V mode
(20 21 22V) +1Vdc for 24v model (40 42 44V) +2Vdc for 48v model
High battery voltage alarm Add +1Vbattery: (high voltage one second one timeafter 30s fault 03) (13.8-14.5V) + 1V for 12V model
(27.6-29V) + 2V for 24v model (55.2-58) + 4V for 48v model
Save mode Loads ≤ 40W (110V) 80W (220V)
AC Input Mode
Input waveform Pure sine wave
Nominal input voltage 200Vac 220Vac 240Vac
Max input voltage 270Vac MAX
Input frequency 50Hz 60Hz (auto sensing)
Efficiency (AC mode) >95% (load, full battery)
Transfer time AC to DC 15ms(typical)
Charge Mode
12V 30A 45A 60A
24V 20A 25A 30A 40A 60A
48V 20A 30A 35A 40A
Min charge current 10A. Change by every 5A
Dimensions
Dimensions (W*H*D) 277*196*466mm 277*186*621mm
Ship Dimensions (W*H*D) 376*306*592mm 376*296*747mm
Warranty One year (standard), 2 years optional (IP20)